Fire Rated Power Cable

Fire Rated Power Cable

The fire rated power cable uses copper or aluminum conductors, fire-resistant insulation, and sheath materials selected by circuit safety level.
Send Inquiry
Description

Our fire rated power cable is engineered for essential circuits that must remain energized during fire exposure. Its layered construction protects conductor separation, slows flame propagation, and supports dependable power to life-safety equipment. Project-specific options can also control smoke, corrosive gas, moisture, and mechanical damage along difficult routes. This makes the cable suitable for emergency networks where continued operation supports evacuation, firefighting, and an orderly equipment shutdown.

 

Product Parameters

 

Parameter

Details

Conductor

Copper or aluminum conductor, configured for the selected model and project design

Insulation

XLPE, PVC, low-smoke halogen-free, or mineral-insulated construction

Fire Resistance

IEC 60331: circuit integrity at 750 C for at least 90 minutes

UL Fire Test

UL 2196: circuit integrity at 950 C for at least 180 minutes

Smoke Requirement

IEC 61034: light transmittance of at least 60 percent for the low-smoke model

Halogen Acid Gas

IEC 60754-1: HCl release no more than 5 percent for the low-halogen model

Application

Fire pump line, emergency lighting line, alarm circuit, smoke exhaust power line

 

Product Advantages

 

 
 

 

The fire rated power cable can keep the circuit connected for a set test period, so key fire equipment has more time to run.

 
 
 

 

Low-smoke and halogen-free options reduce dense smoke and acid gas in indoor escape routes.

 
 
 

 

Armored or waterproof sheath structures can be selected when the line runs through damp tunnels or places with mechanical risk.

 

 

Main Applications

 

This cable is used in emergency lighting systems, fire alarm power circuits, smoke extraction fans, fire pump feeds, and building evacuation routes.

It is also used in underground utility tunnels, high-rise buildings, transport stations, and industrial fire protection circuits.

 

Components

 

Part

Function

Conductor

Carries power or signal current through the circuit.

Fire-resistant insulation

Helps the core keep electrical separation under flame test conditions.

Sheath

Protects the cable against moisture, smoke demand, abrasion, or installation contact.

Armor option

Adds mechanical protection for buried or tunnel sections.

 

560A7787 (1).jpg
560A7874 (1).jpg
FAQ

Q: How should we choose the fire rated power cable standard?

A: The standard should match the project location, building type, circuit role, and fire test requirement.

Q: Can it be supplied as low-smoke halogen-free type?

A: Yes. Low-smoke halogen-free sheath and insulation can be used when the project needs lower smoke and acid gas release.

Q: Which information is needed before production?

A: Rated voltage, conductor size, core number, sheath type, fire test standard, and installation place should be confirmed.

Q: How is the cable packed for delivery?

A: Coils or wooden drums are used by cable size. Drum ends are fixed and the cable surface is protected before shipment.

 

 

 