Fire Retardant Low Smoke Cable

Fire retardant low smoke cable is a special type of cable that effectively suppresses the spread of flames during a fire while producing very little smoke during combustion.
Send Inquiry
Description

Products Description

 

Our factory's fire retardant low smoke cables are mostly low smoke and halogen-free. These cables do not contain halogen materials such as chlorine and bromine, and do not release toxic or corrosive gases when burning, thus avoiding secondary damage to personnel and equipment.

product-400-400

 

Product Model

 

Model Number

Full Name

Insulation Material

Sheath Material

Flame Retardant Rating

Fire Resistance

Low Smoke Halogen-Free

WDZ-BYJ

Halogen-free, low-smoke, flame-retardant copper core cross-linked polyethylene insulated wire

XLPE

Low-smoke halogen-free polyolefins

ZC

No

Yes

WDZB-BYJ

Class B flame-retardant halogen-free low-smoke wire

XLPE

ZB

No

Yes

WDZA-BYJ

Class A flame-retardant halogen-free low-smoke wire

XLPE

ZA

No

Yes

WDZ-YJY

Halogen-free, low-smoke, flame-retardant power cable

XLPE

ZB/ZC

No

Yes

WDZB-YJY 3×25+1×16

Class B flame-retardant, low-smoke, halogen-free power cable

XLPE

ZB

No

Yes

WDZN-YJY

Halogen-free, low-smoke, flame-retardant, fire-resistant power cable

XLPE

ZB

Yes(950℃, 90min)

Yes

WDZAN-YJY

Class A flame-retardant + fire-resistant low-smoke halogen-free cable

XLPE

ZA

Yes(950℃, 180min)

Yes

WDZ-BYJF

Irradiated cross-linked halogen-free, low-smoke, flame-retardant wire

辐照XLPE

ZC

No

Yes

WDZB-BYJ 185mm²

Large cross-section flame-retardant low-smoke wire

XLPE

ZB

No

Yes

 

Product Feature And Application

 

1. Our fire-retardant low-smoke cable can withstand a long-term operating temperature of 150℃, with short-term temperature limits up to 180℃. Its continuous allowable current carrying capacity is 1.5 to 1.6 times that of ordinary conductors of the same specification.

2. At room temperature, our fire-retardant low-smoke cable has the same strength as ordinary aluminum wire, and its mechanical strength retention rate at high temperatures can remain above 90%.

3. Our fire-retardant low-smoke cable has undergone laboratory salt spray testing and outdoor atmospheric exposure testing, showing no significant difference between the two.

4. Our fire-retardant low-smoke cable allows a bending radius of 30 times the cable diameter.

5. The addition of alloy components to this conductor improves its high-temperature performance. Simultaneously, the increased conductor cross-section increases current carrying capacity, improves conductivity, and reduces losses. This reduces power consumption and enhances equipment safety.

 

Product Technical Parameters

 

Nominal cross-section aluminum(mm²)

Calculation section(mm²)

Number of monofilaments(n)

Diameter(mm)

Mass per unit length(kg/km)

Rated breaking force(kN)

DC resistance (20℃)
(Ω/km)

Monofilament

Twisted wire

10

10.0

7

1.35

4.05

27.4

1.69

2.8578

16

16.1

7

1.71

5.10

43.9

2.72

1.7812

25

24.9

7

2.13

6.5

68.1

4.22

1.1480

35

34.4

7

2.50

7.5

93.8

5.81

0.8333

40

40.1

7

2.7

8.1

109.4

6.65

0.7144

50

49.5

7

3.00

9.0

135.1

8.02

0.5787

63

63.2

7

3.39

10.2

172.5

10.24

0.4532

70

71.3

7

3.60

10.8

194.5

11.54

0.4019

95

95.1

7

4.16

12.5

259.8

15.13

0.3010

100

100.1

19

2.59

13.0

274.9

16.92

0.2874

120

121.2

19

2.85

14.3

332.8

20.12

0.2374

125

124.6

19

2.89

14.5

342.3

20.69

0.2309

150

148.1

19

3.15

15.8

406.6

23.99

0.1943

160

159.6

19

3.27

16.4

438.2

25.85

0.1803

185

182.8

19

3.50

17.5

502.0

29.61

0.1574

200

199.9

19

3.66

18.3

548.9

32.38

0.1439

210

209.8

19

3.75

18.8

576.3

34.00

0.1371

240

238.8

19

4.00

20.0

655.6

37.96

0.1205

250

249.6

19

4.09

20.5

685.5

39.69

0.1153

300

297.6

37

3.20

22.4

819.4

48.21

0.0969

315

314.5

37

3.29

23.0

866.1

50.96

0.0917

400

400.0

37

3.71

26.0

1101.4

64.80

0.0721

450

451.1

37

3.94

27.6

1242.2

71.73

0.0639

500

500.5

37

4.15

29.1

1378.1

79.58

0.0576

560

560.0

37

4.39

30.7

1542.1

89.05

0.0515

630

631.3

61

3.63

32.7

1741.2

102.27

0.0458

710

710.1

61

3.85

34.7

1958.7

112.91

0.0407

800

801.4

61

4.09

36.8

2210.5

127.43

0.0360

900

898.2

61

4.33

39.0

2477.5

142.82

0.0322

1000

1000.6

61

4.57

41.1

2759.8

159.09

0.0289

 

FAQ

 

What are the key considerations when purchasing fire retardant low smoke cables?

  • When purchasing fire retardant low smoke cables, it's crucial to adhere to three core principles: compliance certification, scenario matching, and material verification. First, determine the appropriate rating based on the scenario. For densely populated areas, halogen-free, low-smoke cables with a flame retardant rating of Class A or B are mandatory. For ordinary residential buildings, Class C cables can be chosen to balance costs.
  • Second, critical fire-fighting circuits must also possess fire-resistant properties.
  • Finally, rigorously verify the authenticity of the materials. High-quality cables should have high-purity copper conductors and irradiated cross-linked polyolefin insulation, with a smooth and flexible feel. Be wary of excessively low prices, which may indicate adulterated copper cores or halogen-containing sheaths. Request a third-party smoke density and toxicity index test report.

Hot Tags: fire retardant low smoke cable, China fire retardant low smoke cable manufacturers, suppliers, factory, 1 5 mm fire rated cable, fire rated single core cable, fire retardant electrical cables, fire resistant and flame retardant cable, fire resistant low smoke cable, 4 core fire rated cable